Product Description
SSI Super Systems 141.KP.A.NH3 eFlo Meter 2.0
Model No: 141.KP.A.NH3
eFlo 2.0 is SSi’s newest electronic flow measurement instrument line. Like previous eFlo models, the 2.0 line offers simple compatibility with existing controls, making tracking and monitoring gas flows easier than ever. Designed for use in the harshest industrial environments, eFlo allows for easy replacement of manual flow meters and seamlessly integrates into existing control systems.
Features & Benefits:
- Integrated communication via Modbus over RS485 (RTU) and Ethernet (TCP)
- Pressure and temperature compensation for precise flow calculation
- Flow Meter View software and mobile interface for configuration
- Available with electronic valve, with or without control
- Analog control and feedback for data acquisition
- Direct and remote setpoint control
- Built-in high/low flow alarms
- Flow Totalizing
- Compact footprint
- Onboard datalogging
- NIST-traceable calibration
- Precision flow measurement
- USB configuration tools
- Mobile-friendly and web-based remote configuration
- Flow calibration can be certified in use for CQI-9 requirements
- Digital display: easy-to-use touch pad and optional touchscreen
- SCADA integration: Current Flow, Totalized Flow, Setpoint, Cost Calculation
- 2″ NPT
Supported Gases:
- Acetylene Helium
- Air Hydrogen
- Ammonia Hydrogen Chloride
- Argon Hydrogen Sulfide
- Butane Methane
- Carbon Dioxide Natural Gas
- Carbon Monoxide Neon
- Chlorine Nitrogen
- Dissociated Ammonia Nitrous Oxide
- Endothermic Gas (C3H8) Oxygen
- Endothermic Gas (CH4) Propane
- Ethane Sulfur Dioxide
- Ethylene Other (Contact SSi)
- Exothermic Gas
Specifications:
- Power Required: 24VDC @ 400mA
- Accuracy: ±4%
- Turndown Ratio: 6:1
- Gas Temp. Limits: 32°F to 150°F (0°C to 65.6°C)
- Ambient Temp. Limits: 32°F to 150°F (0°C to 65.6°C)
- Flow Output Signal (Linear): 4-20mA
- Max. Output Signal Load: 500Ω
- Input Control Signal (Linear): 4-20mA
- Response Time: 1 – 10 seconds
- Communications: RS485, Ethernet, USB
- Communications Protocol: Modbus RTU, Modbus TCP, EtherNet/IP
- Flow Meter Pressure Limits: 5 psig max.
- Pipe Fitting 1 1/4″ NPT