Product Description
Allen Bradley 100-D115EZJ11 Contactor
PN: 100-D115EZJ11
The Allen Bradley 100-D115EZJ11 Contactor is a 3-pole, 115 amp, IEC contactor with a 24 volt DC electronic coil and one normally open and one normally closed auxiliary contact. It has a conductor size of 6 AWG-300 kcmil and a control voltage of 24 V.
- Voltage type for actuating: DC
- Rated control supply voltage at DC: 24 V
- Type of electrical connection of main circuit: Screw connection
- Rated impulse withstand voltage (Uimp): 12 kV
- Current (Ie), max: 115 A
- Optional overload relays: Electronic
- Current rating: 115 A
- Main current circuit resistance: 0.4 mOhm
- Rated filament current: 120 A @ 230/240V, AC-5b
- Rated isolation voltage (Ui): 600V @ UL, CSA
- Auxiliary contacts: IP20 IEC 60529/DIN 40050
- Rated power (enclosed): 75 Hp @ 460V, 3-phase per UL/CSA
- Rated operational current for contactor: 80 A @ 230V, elevator duty (UL/CSA)
- Rated power for contactor: 75 Hp @ 575V, elevator duty (UL/CSA)
- General purpose current (enclosed): 220 A per UL/CSA
- Power dissipation: 14.5 W @ 400V, AC-3, Ie
- Operating time 9…18 ms @ RC module, closing delay
- Short time withstand (Icw): 1040 A for 10 s, 60 °C (140 °F)
- Coil consumption, hold-in: 8 W @ DC control
- Coil consumption, pick-up: 650VA/310 W @ 50 Hz, 60 Hz, 50/60 Hz
- Switching of 3-phase Capacitors: Single capacitor: 97 kVAR @ 500V, AC-6b, 50 Hz, 40 °C
- Total power dissipation DC control: 22.5 W @ 400V, AC-3, Ie
- Operating limits, dropout: (0.3...0.6) x Us @ DC control
- Switching of lamps: Gas discharge lamps, open: 114 A @ 40 °C (104 °F), AC-5a
- Insulation class of the coil: Class B per VDE 0660, table 22
- Rating for switching AC motors: 80 kW @ 500V, 50 Hz, 3-phase (AC-2, AC-3)
- Switching of hermetically sealed cooling compressor motors: 192 A @ 690V, AC-8a (manual reset of overload release (50 Hz))
- Operating limits, pick-up: (0.85...1.1) x Us @ DC control
- BS88 fuses current rating: Type 2 (per IEC 60947-4-1): 200 A @ 415V, 65 kA available fault current
- UL class: K5 and RK5 fuses rating 250 A @ 600V, 5 kA available fault current per UL 508 and CSA 22.2 No. 14
- Rated voltage (Ue): 690V @ AC, 50/60 Hz
- DIN fuses (gG, gL) current rating Type 2 (per IEC 60947-4-1): 200 A @ 690V, 50 kA available fault current
- Coil voltage 24V DC electronic coil w/ electronic interface
- Rated operational current (Ie): Conventional coil type: 115 A @ 690V, AC-2, AC-3 (50 Hz), ambient temperature 60 °C
- UL class J and CSA HRCI-J fuses rating: Type2 (IEC60947-4-1): 200 A @ 100 kA available fault current per UL verified combination
- UL inverse-time circuit breaker: 150 A @ 600V, 10 kA available fault current per UL listed combination
- Switching of power transformers: Apparent power: 99.8 kVA @ 480V, AC-6a, 60 Hz
- Rated operational power (Pe): 87 kW@ 260V, (50 Hz), ambient temperature 60 °C
- Switching of DC loads: 3-Poles in series: 135 A @ 48/60V (Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-3 at 60 °C)
- Features: Panel mounting only, made of environmentally friendly materials, AC or DC coil control (conventional or electronic), integrated PLC interface (electronic coil)
- Contacts: 3 power poles with external NO and NC side-mounted auxiliary contact, optional side-mounted 2-pole external auxiliary contact blocks
- Conventional coil type: Yes
- Electronic-EI coil type: Yes
- Rated coil frequency: AC 50 Hz, 50/60 Hz DC